Application guide

Balancing pumps in their own bearings

Pump vibration has many possible sources. Correct imbalance only after cavitation, misalignment, pipe strain and bearing condition have been checked.

Specifications checked: September 2026

Vibration sensors mounted on the drive motor and bearing housing of a pumped unit
Vibration sensors mounted on the drive motor and bearing housing of a pumped unit

Direct answer

Can a pump be balanced on site?

Yes, when the unit runs at a stable duty point, both bearing housings are accessible and the 1× component dominates the spectrum. Depending on the design, correction is applied to the motor rotor, coupling or impeller.

Before the first run

Mechanical checks come first

  • Rule out cavitation, suction problems, pipe strain and coupling misalignment first.
  • Check bearing condition, foundation bolts and soft foot on the motor and pump feet.
  • Compare overall vibration with the 1× component. Correct imbalance only when 1× dominates.
Vibration sensors mounted on the drive motor and bearing housing of a pumped unit

Order of work

A controlled balancing sequence

  1. 01

    Run the unit at its normal duty point with stable flow, pressure and speed.

  2. 02

    Mount sensors on both bearing housings of the element being corrected—motor or pump side.

  3. 03

    Record baseline amplitude and phase, then secure a trial weight in the accessible plane: coupling, motor fan or impeller.

  4. 04

    Install the calculated correction at the same radius as the trial weight.

  5. 05

    Verify at the duty point and re-check the readings after the first days of service.

Selection support

Not sure which system fits your machine?

Just write what machine you have — a fan, a crusher, a pump, anything that rotates. Our engineers will take it from there and confirm the right setup before you order.

Ask an engineer